Skip to content

Modes & Overcurrent Protection ​

Both MODE and IS / I-SET share the red RFD indicator LED. All settings are stored in internal EEPROM and retained across power cycles.

1. Operating Mode (MODE Button) ​

To prevent accidental changes, the controller powers up in a mode-locked state. Unlock before switching:

How to Switch Modes ​

  1. Press MODE 5 times consecutively (LED flashes once per tap) and release for 0.8s:
    • The red LED blinks 3 times, resetting to Self-Lock and opening a 6-second change window.
  2. Within 6 seconds, press MODE 1–4 times and release for 0.8s:
    • The red LED blinks 2 times, saving the new mode and locking again immediately.
PressesModeBehavior
1Self-Lock (Default)Tap to start continuous run; tap same direction to stop, or opposite direction to stop and reverse; stops automatically at limit
2Inching (Jog)Runs only while K1/K2 or app button is held; stops immediately on release
3Infinite LoopRuns continuously between LS1 and LS2 limits until manually stopped
4Single CycleCompletes one full round-trip (two limit triggers) and stops automatically

Emergency Stop

In any mode, pressing K1 + K2 simultaneously (or tapping Stop in the Mini Program) stops the motor immediately. Both keys must be released before resuming.


2. Overcurrent Protection (IS / I-SET Button) ​

  • Range: 1A – 10A (number of taps = amperes; default 5A, saved in EEPROM).
  • How to Set:
    1. Press I-SET N times consecutively (N = 1 ~ 10, e.g. 3 taps for 3A). The LED flashes once per tap.
    2. Release for 0.8s. After a brief 200ms pause, the red LED blinks N times to confirm the saved threshold.
    3. More than 10 taps are ignored to prevent accidental misconfiguration.

Trip & Recovery Behavior ​

  • Startup Inrush Blanking: Ignores motor startup surge current for the first 500ms after each start.
  • Overcurrent Trip: If current exceeds the threshold continuously for ~50ms, the relays cut off immediately and the RFD red LED stays solid ON.
  • Recovery: Clear any mechanical jam or overload, then restart the motor (release button first in Inching mode) or press a setup key to clear the fault LED.